Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 2/2024

11.10.2023 | Original Article

Total-body PET/CT with half-dose [68 Ga]Ga-PSMA-11 for biochemical recurrent prostate cancer: comparable diagnostic value to short axial field-of-view PET/CT with full-dose [68 Ga]Ga-PSMA-11

verfasst von: Yuheng Liu, Lianghua Li, Yanyu Qin, Zijun Chen, Haitao Zhao, Xinlu Wang, Ruohua Chen

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 2/2024

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The objective of this study was to evaluate the diagnostic performance and image quality of total-body positron emission tomography/computed tomography (PET/CT) imaging using a half-dose of [68 Ga]Ga-prostate specific membrane antigen ([68 Ga]Ga-PSMA) radiotracer, compared to conventional short axial field-of-view PET/CT imaging using a full dose of [68 Ga]Ga-PSMA.

Methods

This retrospective study enrolled 52 patients with biochemical recurrent (BCR) prostate cancer after radical prostatectomy who underwent total-body PET/CT with a half-dose (0.9–1.1 MBq/kg) of [68 Ga]Ga-PSMA. These patients were matched by baseline characteristics to another 52 BCR patients after prostatectomy who underwent conventional PET/CT with a full dose (1.8–2.2 MBq/kg) of [68 Ga]Ga-PSMA. The half-dose group was further divided into 5-min (G5) and 2-min (G2) acquisition subgroups. Image quality was assessed through subjective analysis using a 5-point scale and objective measurements of standard uptake value maximum (SUVmax), standard uptake value mean (SUVmean), background variation (BV) of the liver, blood pool, and parotid glands. Additionally, SUVmax and tumor-to-background ratio (TBR) were calculated for lesions.

Results

No significant difference in subjective image quality was found between the G2 and full-dose groups (p > 0.05). PET/CT image quality was significantly higher for the G5 versus G2 (p < 0.001) and full-dose groups (p < 0.001). TBR did not differ between the G2 and full-dose groups (4.23 ± 5.21 vs 4.22 ± 3.97, p = 0.99). Liver BV was significantly lower for G2 versus full-dose groups (0.16 ± 0.03 vs 0.20 ± 0.05, p < 0.001).

Conclusions

Total-body PET/CT with a half-dose [68 Ga]Ga-PSMA yields image quality superior or comparable to that of conventional PET/CT. The utilization of total-body [68 Ga]Ga-PSMA PET/CT meets the diagnostic demands of BCR patients, particularly those who exhibit reduced tolerance to prolonged horizontal positioning and scan durations, while simultaneously reducing radiation exposure for the subjects.
Literatur
17.
Zurück zum Zitat Halpern BS, Dahlbom M, Quon A, Schiepers C, Waldherr C, Silverman DH, et al. Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability. J Nucl Med. 2004;45:797–801. Halpern BS, Dahlbom M, Quon A, Schiepers C, Waldherr C, Silverman DH, et al. Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability. J Nucl Med. 2004;45:797–801.
Metadaten
Titel
Total-body PET/CT with half-dose [68 Ga]Ga-PSMA-11 for biochemical recurrent prostate cancer: comparable diagnostic value to short axial field-of-view PET/CT with full-dose [68 Ga]Ga-PSMA-11
verfasst von
Yuheng Liu
Lianghua Li
Yanyu Qin
Zijun Chen
Haitao Zhao
Xinlu Wang
Ruohua Chen
Publikationsdatum
11.10.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 2/2024
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-023-06466-z

Weitere Artikel der Ausgabe 2/2024

European Journal of Nuclear Medicine and Molecular Imaging 2/2024 Zur Ausgabe