The repeatability of periodontal imaging with intraoral ultrasound scanning

verfasst von: Carlos Alberto Figueredo, Hollis Lai, Monica P. Gibson, Lawrence H. Le, Fabiana T. Almeida, Paul W. Major

Erschienen in: Clinical Oral Investigations | Ausgabe 3/2024

Einloggen, um Zugang zu erhalten

Abstract

Objective

Ultrasound is a non-invasive and low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess the periodontium by comparing it to current imaging methods. This study aims to characterize the repeatability of intraoral periodontal ultrasound imaging.

Materials and methods

Two hundred and twenty-three teeth were scanned from fourteen volunteers participating in this study. One operator conducted all the scans in each tooth thrice with a 20 MHz intraoral ultrasound. The repeatability of three measurements, alveolar bone crest to the cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT), was calculated with intercorrelation coefficient (ICC). Measurements were also compared with mean absolute deviation (MAD), repeatability coefficient (RC), and descriptive statistics.

Results

ICC scores for intra-rater repeatability were 0.917(0.897,0.933), 0.849(0.816,0.878), and 0.790(0.746,0.898), MAD results were 0.610 mm (± 0.508), 0.224 (± 0.200), and 0.067 (± 0.060), and RC results were 0.648, 0.327, and 0.121 for ABC-CEJ, GT, and ABT measurements, respectively.

Conclusion

Results of the present study pointed towards good or excellent repeatability of ultrasound as a measurement tool for periodontal structures.

Clinical relevance

Clinicians could benefit from the introduction of a novel chairside diagnostic tool. Ultrasound is a non-invasive imaging assessment tool for the periodontium with promising results in the literature. Further validation, establishment of scanning protocols, and commercialization are still needed before ultrasound imaging is available for clinicians.
Literatur
12.
Zurück zum Zitat Dhondt R, Quirynen M, Tarce M, Teughels W, Temmerman A, Jacobs R (2022) The accuracy of probing, ultrasound and cone-beam CT scans for determining the buccal bone plate dimensions around oral implants – A systematic review. J Periodontal Res Aug 57(4):754–767. https://doi.org/10.1111/jre.12998CrossRef Dhondt R, Quirynen M, Tarce M, Teughels W, Temmerman A, Jacobs R (2022) The accuracy of probing, ultrasound and cone-beam CT scans for determining the buccal bone plate dimensions around oral implants – A systematic review. J Periodontal Res Aug 57(4):754–767. https://​doi.​org/​10.​1111/​jre.​12998CrossRef
17.
Zurück zum Zitat Majzoub J, Tavelli L, Barootchi S, Salami A, Inglehart MR, Kripfgans OD et al (2022) Agreement in measurements of ultrasonography-derived periodontal diagnostic parameters among multiple raters: a diagnostic accuracy study. Oral surg oral Med oral pathol oral Radiol. 134(3):375–385. https://doi.org/10.1016/j.oooo.2022.03.010 Majzoub J, Tavelli L, Barootchi S, Salami A, Inglehart MR, Kripfgans OD et al (2022) Agreement in measurements of ultrasonography-derived periodontal diagnostic parameters among multiple raters: a diagnostic accuracy study. Oral surg oral Med oral pathol oral Radiol. 134(3):375–385. https://​doi.​org/​10.​1016/​j.​oooo.​2022.​03.​010
18.
23.
Zurück zum Zitat Chifor R, Badea ME, Hedeşiu M, Chifor I (2015) Identification of the anatomical elements used in periodontal diagnosis on 40 MHz periodontal ultrasonography. Rom J Morphol Embryol 56(1):149–153PubMed Chifor R, Badea ME, Hedeşiu M, Chifor I (2015) Identification of the anatomical elements used in periodontal diagnosis on 40 MHz periodontal ultrasonography. Rom J Morphol Embryol 56(1):149–153PubMed
Metadaten
Titel
The repeatability of periodontal imaging with intraoral ultrasound scanning
verfasst von
Carlos Alberto Figueredo
Hollis Lai
Monica P. Gibson
Lawrence H. Le
Fabiana T. Almeida
Paul W. Major
Publikationsdatum
01.03.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 3/2024
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-024-05564-y

Weitere Artikel der Ausgabe 3/2024

Clinical Oral Investigations 3/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.