Erschienen in: BMC Medical Imaging 1/2019

Open Access 01.12.2019 | Research article

Non-contrast-enhanced magnetic resonance angiography of facial arteries for pre-operative evaluation of vascularized submental lymph node flaps

verfasst von: Ming-Chen Wu, Ming-Yi Hsu, Ren-Fu Shie, Ming-Huei Cheng, Fang-I Chu, Chien-Yuan Lin, Yui-Ping Fan, Sung-Yu Chu

Erschienen in: BMC Medical Imaging | Ausgabe 1/2019

Abstract

Background

The aim of this study was to compare non-contrast-enhanced 3D phase contrast magnetic resonance angiography (3D PC-MRA) and conventional intravenous administration of contrast media, i.e., contrast-enhanced MRA (CE-MRA), to evaluate the courses of facial arteries for the preparation of vascularized submental lymph node flap (VSLN flap) transfer.

Methods

The head and neck regions of 20 patients with limb lymphedema were imaged using a 3 T MRI scanner. To improve the evaluation of facial artery courses, MRA was fused with anatomical structures generated by high-resolution T1-weighted imaging. The diagnostic and image qualities of facial arteries for VSLN flap planning were independently rated by two radiologists. Interobserver agreement was evaluated using Cohen’s kappa. Differences between 3D PC-MRA and CE-MRA in terms of the diagnostic quality of facial arteries were evaluated using McNemar’s test.

Results

Cohen’s kappa indicated fair to good interobserver agreement for the diagnostic and image qualities of the bilateral facial arteries. No significant difference in terms of the diagnostic quality of the left and right facial arteries between 3D PC-MRA and CE-MRA, respectively, was identified.

Conclusions

Non-contrast 3D PC-MRA is a reliable method for the evaluation of facial artery courses prior to VSLN flap transfer and could serve as an alternative to CE-MRA for patients with renal insufficiency or severe adverse reactions to contrast media.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
3D PC-MRA
Three-dimensional phase contrast magnetic resonance angiography
3T
Three Tesla
CE
Contrast-enhanced
CE-MRA
Contrast-enhanced magnetic resonance angiography
CM
Contrast media
CTA
Contrast media-enhanced computed tomography angiography
FOV
Field-of-view
LNs
Lymph nodes
MIP
Maximum intensity projection
MRI
Magnetic resonance imaging
TE
Echo time
TR
Repetition time
VENC
Velocity encoding
Volume-T1
Three-dimensional fast spin-echo T1-weighted image
Volume-T2
Three-dimensional fast spin-echo T2-weighted image
VSLN flap
Vascularized submental lymph node flap

Background

Lymphedema is a disease characterized by the abnormal collection of fluid and proteins in the interstitial space. The lymphedema could be due to congenital lymphatic dysplasia (primary lymphedema), anatomic obliteration (secondary lymphedema, such as after radical dissection, irradiation, repeated lymphangitis) or consequence of functional deficiency. Treatment of lymphedema includes conservative methods such as drug therapy, complex decongestive therapy, and more invasive methods, e.g., debulking surgery and microsurgery [1]. Recently, a vascularized submental lymph node flap (VSLN flap) with a facial vascular pedicle was developed for the treatment of limb lymphedema [27]. Contrast-enhanced (CE) magnetic resonance angiography (CE-MRA) and computed tomography angiography (CTA) are used to evaluate the main arteries of the maxillofacial region, particularly the facial arteries [812]. Non-CE-MRA also has been used to evaluate the carotid and intracranial main arteries [13, 14], but only one article to date has focused on the main arteries of the maxillofacial region. Sakai et al. proposed non-CE four-dimensional MRA with modified true fast imaging and steady-state free precession as well as a flow-sensitive alternating inversion recovery scheme for spin tagging of blood labeling sequences using a three Tesla (3 T) magnetic resonance imaging (MRI) system to evaluate 15 patients with head and neck tumors [15]. In this study, 81% of facial arteries were identified by two independent radiologists, but no other study has applied this method for the clinical evaluation of facial arteries.
In October 2010, a 3 T MRI system with a commercialized non-CE-MRA technique using three-dimensional phase contrast (PC) MRA (3D PC-MRA) was installed at our institute [16]. Unlike traditional PC-MRA, 3D PC-MRA is compatible with parallel imaging and uses a time-efficient elliptical k-space-filling technique to reduce scan time and influence patient motions, especially in children and the elderly. The aim of present study was to compare the performances of non-CE 3D PC-MRA and CE-MRA in terms of visualization of the facial arteries.

Methods

Patients

The study protocol was approved by the Chang Gung Medical Foundation Institutional Review Board (101–3481-B), and all participants provided an informed consent. Between January 2014 and April 2015, a total of 20 patients with limb lymphedema (1 male and 19 females; mean age: 54.9 years; age range: 2–70 years) as confirmed by lymphoscintigraphy preoperatively underwent MRI for VSLN flap transfer. None of the patients had a history of surgery for cancer of the head and neck region.

MRI technique

All MRI examinations were performed using a 3 T clinical scanner (Discovery MR750; GE Healthcare, Milwaukee, WI, USA) equipped with an 8-channel brain coil for signal detection and body coil for radio frequency transmission. The MRI field-of-view (FOV) was 300 mm, and the tongue base area was placed at the center of FOV. The order of the scanning sequences were as follows: 3D fast spin-echo T1-weighted image (Volume-T1), 3D fast spin-echo T2-weighted image (Volume-T2), 3D PC-MRA, and CE-MRA. To better depict the courses of facial arteries, a facial anatomical reference was acquired by Volume-T1 in the sagittal view with a repetition time (TR) of 600 ms, echo time (TE) of 13 ms, FOV of 160 mm, and slab thickness of 12 mm. Similarly, to better identify the submandibular and submental lymph nodes (LNs), fat-saturated Volume-T2 was applied in the sagittal view with a TR of 2500 ms, TE of 76 ms, FOV of 160 mm, and slab thickness of 12 mm. Images were acquired by 3D PC-MRA and CE-MRA under matched slice coverage and resolution. The scanning parameters are summarized in Table 1. The acquisition time for CE-MRA was optimized, and trigger delay was set at 2 s following intravenous administration of 0.2 mmol/kg gadopentetate dimeglumine (Bayer Pharma AG, Wuppertal, Germany) to maximize the signal intensity of the branches of facial arteries in accordance with the findings of a MRA data trial conducted in our department. The stay duration of patients in the MRI room was approximately 25–30 min. Further, the acquisition time of 3D PC-MRA was 161 s, whereas that for CE-MRA was 119 s.
Table 1
Imaging parameters
 
3D PC-MRA
CE-MRA
Field-of-view (mm)
300
300
Matrix size (mm)
352 × 224
352 × 224
Slice thickness (mm)
1.6
1.6
Repetition time (ms)
8.9
3.9
Echo time (ms)
3.9
1.4
Orientation of acquisition
Coronal
Coronal
Scan time (min:s)
02:41
01:59
3D PC-MRA 3D phase magnetic resonance angiography, CE-MRA Contrast-enhanced magnetic resonance angiography

Data analysis

Postprocessing of the MRI data was interactively performed using the integrated registration function of a standard workstation (AW VolumeShare 5; GE Healthcare, Waukesha, WI, USA). Slabs of 18 mm thickness were generated by maximum intensity projection (MIP) of Volume-T1 with 3D PC-MRA or CE-MRA. A total of 40 facial arteries of 20 anonymized patients were evaluated using 3D PC-MRA and CE-MRA. Further, MRA diagnosis and image quality for the visualization of facial arteries were assessed by two board-certified radiologists with 11- and 7-year experience in evaluating MRA images, respectively, who were blinded to patient information and imaging technique. The radiologists rated the diagnostic and image qualities of facial arteries using a four-point scale: 0 = poor quality of facial arteries with nondiagnostic quality (Fig. 1a); 1 = questionable or partial visualization of facial arteries with nondiagnostic quality (Fig. 1b); 2 = partial visualization of facial arteries with diagnostic quality (Fig. 1c); and 3 = good to excellent image with diagnostic quality (Fig. 1d).

Statistical analysis

Statistical analysis were conducted to determine whether the diagnostic quality of facial arteries differed between 3D PC-MRA and CE-MRA. The obtained image quality score from the two radiologists was used as an indicator of image clarity obtained using 3D PC-MRA and CE-MRA. Diagnostic quality was further denoted as a categorical variable wherein an image quality score of 2 or 3 was considered diagnostic and a score of 0 or 1 was considered nondiagnostic. Interobserver agreement between the two radiologists was evaluated using Cohen’s kappa statistic [17]; Fleiss’s arbitrary guidelines characterize kappas > 0.75 as excellent, 0.40–0.75 as fair to good, and < 0.40 as poor [18]. For the facial arteries of the right and left sides, respectively, difference in terms of diagnostic quality between 3D PC-MRA and CE-MRA was assessed using McNemar’s test. All analysis were conducted using R software [19]. A p-value of < 0.05 was considered statistically significant.

Results

All 40 facial arteries from 20 patients were successfully imaged using 3D PC-MRA and CE-MRA. Of these, 15 arteries (37.5%) imaged using 3D PC-MRA (Fig. 2a) and 21 (52.5%) using CE-MRA (Fig. 2b) were exactly delineated by both radiologists. Because the enhancement of facial arteries is associated with contrast media (CM)-induced T1-shortening of the blood, it may be sometimes difficult to differentiate the small arteries from neighboring tissues due to CM contamination with CE-MRA compared with 3D PC-MRA (Fig. 3). For 1 of the 20 patients, the signals of facial arteries were lost with 3D PC-MRA but not with CE-MRA (Fig. 4).
The radiologists rated vascular morphology by MIP of Volume-T1 fused with 3D PC-MRA or CE-MRA using a four-point scale. The results are summarized in Table 2. Regarding the image quality of the right and left facial arteries on the images acquired with 3D PC-MRA, the estimated Cohen’s kappa were 0.67 and 0.55, respectively, indicating fair to good agreement. As shown by the summary of McNemar’s test results in Table 3, no significant difference in terms of diagnostic quality between the images acquired with 3D PC-MRA and those acquired with CE-MRA was identified. The image quality scores are summarized in Table 4.
Table 2
Image and diagnostic quality scores by two ratersImage quality score, 0–3
Patient
Image Quality
Diagnostic Quality
Right
Left
Right
Left
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-
MRA Rater 1
CE-MRA Rater 2
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-MRA Rater 1
CE-MRA Rater 2
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-MRA Rater 1
CE-MRA Rater 2
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-MRA Rater 1
CE-MRA Rater 2
1
2
2
3
2
1
1
3
3
D
D
D
D
N
N
D
D
2
3
3
3
3
3
3
3
3
D
D
D
D
D
D
D
D
3
2
3
3
3
2
2
2
2
D
D
D
D
D
D
D
D
4
0
0
3
2
1
2
3
2
N
N
D
D
N
D
D
D
5
2
2
3
3
2
2
3
2
D
D
D
D
D
D
D
D
6
3
3
3
3
3
3
3
3
D
D
D
D
D
D
D
D
7
3
3
3
3
2
2
3
3
D
D
D
D
D
D
D
D
8
2
1
2
2
3
2
3
3
D
N
D
D
D
D
D
D
9
2
2
1
2
2
2
2
2
D
D
N
D
D
D
D
D
10
3
3
3
3
3
3
3
3
D
D
D
D
D
D
D
D
11
3
3
0
0
3
2
0
0
D
D
N
N
D
D
N
N
12
3
3
3
3
2
2
2
2
D
D
D
D
D
D
D
D
13
2
1
2
2
2
2
3
3
D
N
D
D
D
D
D
D
14
3
3
3
3
1
2
3
2
D
D
D
D
N
D
D
D
15
3
3
2
2
0
0
0
0
D
D
D
D
N
N
N
N
16
2
2
3
3
1
1
3
2
D
D
D
D
N
N
D
D
17
2
1
3
3
2
1
3
2
D
N
D
D
D
N
D
D
18
3
3
3
3
3
2
3
2
D
D
D
D
D
D
D
D
19
3
3
3
3
3
3
3
3
D
D
D
D
D
D
D
D
20
2
2
3
3
3
3
3
3
D
D
D
D
D
D
D
D
Cohen’s kappa
0.67
0.68
0.56
0.49
0.35
0.64
0.571
1
Diagnostic score, N: nondiagnostic; D: diagnostic
3D PC-MRA 3D phase magnetic resonance angiography, CE-MRA Contrast-enhanced magnetic resonance angiography
Table 3
Obtained p-values using McNemar’s test to access differences between 3D phase magnetic resonance angiography and contrast-enhanced magnetic resonance angiography
 
Rater 1
Rater 2
Right side
1
0.37
Left side
0.37
0.62
Table 4
Summary of image quality scores of the bilateral facial arteries by the two raters
SCORE
Right facial artery
Left facial artery
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-MRA Rater 1
CE-MRA Rater 2
3D PC-MRA Rater 1
3D PC-MRA Rater 2
CE-MRA Rater 1
CE-MRA Rater 2
0
1
1
1
1
1
1
2
2
1
0
3
1
0
4
3
0
0
2
9
5
3
6
7
11
3
9
3
10 (50%)
11 (55%)
15 (75%)
13 (65%)
8 (40%)
5 (25%)
15 (75%)
9 (45%)
3D PC-MRA: 3D phase magnetic resonance angiography, CE-MRA: contrast-enhanced magnetic resonance angiography

Discussion

To date, a limited number of articles have proposed the use of sonography, computed tomography, and MRI to evaluate the submandibular and submental LNs within VSLN flap [2, 2022], but no study has explored the relationship between the submandibular glands and facial arteries during VSLN flap transfer. Pre-operative evaluation of LNs within VSLN flap and the courses of facial arteries prior to VSLN flap transfer is important, especially to determine the relationship while planning the ligation of branches to the submandibular glands and to reduce the surgical duration required to prepare facial arteries [23, 24]. The use of CM-enhanced CTA or MRA could facilitate the elucidation of the relationship between the submandibular glands and facial arteries prior to VSLN flap transfer. Although the cost and examination time of CTA are lower than those of MRA, the latter is more favorable owing to the lack of radiation exposure [25] and no risk of CM-induced nephropathy [2628].
With a proper setting of acquisition timing following the administration of intravenous CM injection, CE-MRA is considered a promising method for the visualization of facial arteries [2, 811]. However, two factors should be considered when applying CE-MRA: complication of the delineation of facial arteries due to CM contamination of neighboring tissues (Fig. 3b) and potential risk of nephrogenic systemic fibrosis following the administration of gadolinium-based CM in patients with renal insufficiency [27, 29, 30]. Non-CE-MRA is a viable alternative method for the visualization of the main arteries in the neck region. 3D PC-MRA based on blood flow velocity has minimal background tissue intensity and demonstrates comparable results to CE-MRA in terms of the visualization of facial arteries (Figs. 2 and 3). In this study, there was no significant difference between CE-MRA and 3D PC-MRA in terms of the diagnostic abilities of facial arteries. The signal loss of facial arteries with 3D PC-MRA in one patient (Fig. 4) may be attributable to flow change, suggesting that an improper velocity encoding (VENC) value was used. An automatic method for rapid determination of a suitable range of the VENC values of specific vessels would be helpful when applying 3D PC-MRA to avoid blood flow perturbations.
Regarding image quality, on an average, 65 and 42.5% of the images for bilateral facial arteries with CE-MRA and 3D PC-MRA, respectively, had a score of at least 3, suggesting that image quality may be better with CE-MRA. However, further investigations with larger cohorts are necessary to identify significant differences in terms of image quality scores.
Despite the potential differences in terms of image quality between CE-MRA and 3D PC-MRA, the difference in terms of diagnostic quality between both methods was consistently insignificant for the bilateral facial arteries. Three dimensional PC-MRA, a noninvasive method, has a lower cost and no risk of adverse reactions from CM; thus, radiologists should first consider 3D PC-MRA for pre-operative planning of VSLN flap transfer. With no intravenous administration of CM, 3D PC-MRA can be immediately repeated if image quality is unsatisfactory and can relieve anxiety and stress among children during the placement of an intravenous catheter. CE-MRA should be considered a bailout method when the results of 3D PC-MRA are consistently unsatisfactory. On the other hand, 3D PC-MRA could serve as an alternative method for CE-MRA failure due to motion artifacts or missed optimal acquisition timing.
There were two limitations to this study that should be addressed. First, the branches and perforators of facial arteries were not evaluated. CTA can be used for the pre-operative evaluation of perforators during flap transfer [31, 32], whereas CE-MRA with a small FOV is better for imaging facial arteries and branches and perforators. However, the signal-to-noise ratio of image quality due to a small FOV remains problematic, and scan time increases due to repeated studies of the right and left facial arteries. To the best of our knowledge, no study has yet examined the efficiency of non-CE-MRA in the evaluation of small vessels, such as perforators, or the branches of the main arteries of the maxillofacial region. Thus, the next stage is to image the branches and perforators with 3D PC-MRA. Second, the sample size of this study was relatively small (i.e., 20 patients); therefore, further evaluations using larger population size is necessary to verify these results.

Conclusions

3D PC-MRA is a reliable method for the evaluation of facial artery course during the planning of VSLN flap transfer. 3D PC-MRA provides similar diagnostic accuracy and acceptable image quality compared to CE-MRA, without the risk of adverse drug reactions due to CM or nephrogenic systemic fibrosis. Consequently, 3D PC-MRA is expected to be widely applied to improve the diagnostic value of the visualization of small arterial branches.

Acknowledgements

We would like to thank Ms. Tseng from the Center for Big Data Analytics (CLRPG3D0043) of Chang Gung Memorial Hospital for statistical consultation and Enago (SUNCBT-5) for langurage editing.
Chang Gung Medical Foundation Institutional Review Board (101–3481-B), and all participants provided an informed consent.
Not Applicable.

Competing interests

Mr. Chien-Yuan Lin declares conflict of interest as an employee of GE Healthcare, Taiwan.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat International Society of L. The diagnosis and treatment of peripheral lymphedema: 2016 consensus document of the international society of lymphology. Lymphology. 2016;49:170–84. International Society of L. The diagnosis and treatment of peripheral lymphedema: 2016 consensus document of the international society of lymphology. Lymphology. 2016;49:170–84.
2.
Zurück zum Zitat Patel KM, Chu SY, Huang JJ, Wu CW, Lin CY, Cheng MH. Preplanning vascularized lymph node transfer with duplex ultrasonography: an evaluation of 3 donor sites. Plast Reconstr Surg Glob Open. 2014;2:e193.CrossRef Patel KM, Chu SY, Huang JJ, Wu CW, Lin CY, Cheng MH. Preplanning vascularized lymph node transfer with duplex ultrasonography: an evaluation of 3 donor sites. Plast Reconstr Surg Glob Open. 2014;2:e193.CrossRef
3.
Zurück zum Zitat Cheng MH, Chen SC, Henry SL, Tan BK, Lin MC, Huang JJ. Vascularized groin lymph node flap transfer for postmastectomy upper limb lymphedema: flap anatomy, recipient sites, and outcomes. Plast Reconstr Surg. 2013;131:1286–98.CrossRef Cheng MH, Chen SC, Henry SL, Tan BK, Lin MC, Huang JJ. Vascularized groin lymph node flap transfer for postmastectomy upper limb lymphedema: flap anatomy, recipient sites, and outcomes. Plast Reconstr Surg. 2013;131:1286–98.CrossRef
4.
Zurück zum Zitat Patel KM, Lin CY, Cheng MH. From theory to evidence: long-term evaluation of the mechanism of action and flap integration of distal vascularized lymph node transfers. J Reconstr Microsurg. 2015;31:26–30.CrossRef Patel KM, Lin CY, Cheng MH. From theory to evidence: long-term evaluation of the mechanism of action and flap integration of distal vascularized lymph node transfers. J Reconstr Microsurg. 2015;31:26–30.CrossRef
5.
Zurück zum Zitat Pannucci CJ, Gerety PA, Wang AR, Zhang P, Mies C, Kanchwala SK. Feasibility of the internal mammary lymph node flap as a vascularized lymph node transfer: a cadaveric dissection study. Microsurgery. 2016;36(6):485–90.CrossRef Pannucci CJ, Gerety PA, Wang AR, Zhang P, Mies C, Kanchwala SK. Feasibility of the internal mammary lymph node flap as a vascularized lymph node transfer: a cadaveric dissection study. Microsurgery. 2016;36(6):485–90.CrossRef
6.
Zurück zum Zitat Lin CH, Ali R, Chen SC, et al. Vascularized groin lymph node transfer using the wrist as a recipient site for management of postmastectomy upper extremity lymphedema. Plast Reconstr Surg. 2009;123:1265–75.CrossRef Lin CH, Ali R, Chen SC, et al. Vascularized groin lymph node transfer using the wrist as a recipient site for management of postmastectomy upper extremity lymphedema. Plast Reconstr Surg. 2009;123:1265–75.CrossRef
7.
Zurück zum Zitat Cheng MH, Huang JJ, Nguyen DH, et al. A novel approach to the treatment of lower extremity lymphedema by transferring a vascularized submental lymph node flap to the ankle. Gynecol Oncol. 2012;126:93–8.CrossRef Cheng MH, Huang JJ, Nguyen DH, et al. A novel approach to the treatment of lower extremity lymphedema by transferring a vascularized submental lymph node flap to the ankle. Gynecol Oncol. 2012;126:93–8.CrossRef
8.
Zurück zum Zitat Leclerc X, Gauvrit JY, Nicol L, Pruvo JP. Contrast-enhanced MR angiography of the craniocervical vessels: a review. Neuroradiology. 1999;41:867–74.CrossRef Leclerc X, Gauvrit JY, Nicol L, Pruvo JP. Contrast-enhanced MR angiography of the craniocervical vessels: a review. Neuroradiology. 1999;41:867–74.CrossRef
9.
Zurück zum Zitat Kramer M, Schwab SA, Nkenke E, et al. Whole body magnetic resonance angiography and computed tomography angiography in the vascular mapping of head and neck: an intraindividual comparison. Head Face Med. 2014;10:16.CrossRef Kramer M, Schwab SA, Nkenke E, et al. Whole body magnetic resonance angiography and computed tomography angiography in the vascular mapping of head and neck: an intraindividual comparison. Head Face Med. 2014;10:16.CrossRef
10.
Zurück zum Zitat Kramer M, Nkenke E, Kikuchi K, et al. Whole-body magnetic resonance angiography for presurgical planning of free-flap head and neck reconstruction. Eur J Radiol. 2012;81:262–6.CrossRef Kramer M, Nkenke E, Kikuchi K, et al. Whole-body magnetic resonance angiography for presurgical planning of free-flap head and neck reconstruction. Eur J Radiol. 2012;81:262–6.CrossRef
11.
Zurück zum Zitat Razek AA, Gaballa G, Megahed AS, Elmogy E. Time resolved imaging of contrast kinetics (TRICKS) MR angiography of arteriovenous malformations of head and neck. Eur J Radiol. 2013;82:1885–91.CrossRef Razek AA, Gaballa G, Megahed AS, Elmogy E. Time resolved imaging of contrast kinetics (TRICKS) MR angiography of arteriovenous malformations of head and neck. Eur J Radiol. 2013;82:1885–91.CrossRef
12.
Zurück zum Zitat Abdel Razek AA, Denewer AT, Hegazy MA, Hafez MT. Role of computed tomography angiography in the diagnosis of vascular stenosis in head and neck microvascular free flap reconstruction. Int J Oral Maxillofac Surg. 2014;43:811–5.CrossRef Abdel Razek AA, Denewer AT, Hegazy MA, Hafez MT. Role of computed tomography angiography in the diagnosis of vascular stenosis in head and neck microvascular free flap reconstruction. Int J Oral Maxillofac Surg. 2014;43:811–5.CrossRef
13.
Zurück zum Zitat DeLano MC, DeMarco JK. 3.0 T versus 1.5 T MR angiography of the head and neck. Neuroimaging Clin N Am. 2006;16:321–41 xi.CrossRef DeLano MC, DeMarco JK. 3.0 T versus 1.5 T MR angiography of the head and neck. Neuroimaging Clin N Am. 2006;16:321–41 xi.CrossRef
14.
Zurück zum Zitat Lim RP, Koktzoglou I. Noncontrast magnetic resonance angiography: concepts and clinical applications. Radiol Clin North Am. 2015;53:457–76.CrossRef Lim RP, Koktzoglou I. Noncontrast magnetic resonance angiography: concepts and clinical applications. Radiol Clin North Am. 2015;53:457–76.CrossRef
15.
Zurück zum Zitat Sakai M, Illies T, Jerusel N, et al. Feasibility of non-contrast-enhanced four dimensional (4D) MRA in head and neck tumors, comparison with contrast-enhanced 4D MRA. Springerplus. 2016;5:1282.CrossRef Sakai M, Illies T, Jerusel N, et al. Feasibility of non-contrast-enhanced four dimensional (4D) MRA in head and neck tumors, comparison with contrast-enhanced 4D MRA. Springerplus. 2016;5:1282.CrossRef
16.
Zurück zum Zitat Lummel N, Boeckh-Behrens T, Lutz J, Burke M, Linn J. Evaluation of the supraaortic arteries using non-contrast-enhanced velocity MR angiography “Inhance”. Neuroradiology. 2012;54:1215–9.CrossRef Lummel N, Boeckh-Behrens T, Lutz J, Burke M, Linn J. Evaluation of the supraaortic arteries using non-contrast-enhanced velocity MR angiography “Inhance”. Neuroradiology. 2012;54:1215–9.CrossRef
17.
Zurück zum Zitat Mc NQ. Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika. 1947;12:153–7.CrossRef Mc NQ. Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika. 1947;12:153–7.CrossRef
18.
Zurück zum Zitat Fleiss JL. Stastitical methods for rates and proportions (2nd ed.). New York: Wiley; 1981. ISBN 0–471–26370-2 Fleiss JL. Stastitical methods for rates and proportions (2nd ed.). New York: Wiley; 1981. ISBN 0–471–26370-2
20.
Zurück zum Zitat Mullan D, Kosutic D. Contrast CT-scan for preoperative planning of VSLN (vascularized submental lymph-node) transfer. J Surg Oncol. 2017;115:23–6.CrossRef Mullan D, Kosutic D. Contrast CT-scan for preoperative planning of VSLN (vascularized submental lymph-node) transfer. J Surg Oncol. 2017;115:23–6.CrossRef
21.
Zurück zum Zitat Asuncion MO, Chu SY, Huang YL, Lin CY, Cheng MH. Accurate prediction of submental lymph nodes using magnetic resonance imaging for lymphedema surgery. Plast Reconstr Surg Glob Open. 2018;6:e1691.CrossRef Asuncion MO, Chu SY, Huang YL, Lin CY, Cheng MH. Accurate prediction of submental lymph nodes using magnetic resonance imaging for lymphedema surgery. Plast Reconstr Surg Glob Open. 2018;6:e1691.CrossRef
22.
Zurück zum Zitat Gustafsson J, Chu SY, Chan WH, Cheng MH. Correlation between quantity of transferred lymph nodes and outcome in vascularized submental lymph node flap transfer for lower limb lymphedema. Plast Reconstr Surg. 2018;142(4):1056–63.CrossRef Gustafsson J, Chu SY, Chan WH, Cheng MH. Correlation between quantity of transferred lymph nodes and outcome in vascularized submental lymph node flap transfer for lower limb lymphedema. Plast Reconstr Surg. 2018;142(4):1056–63.CrossRef
23.
Zurück zum Zitat Pistre V, Pelissier P, Martin D, Lim A, Baudet J. Ten years of experience with the submental flap. Plast Reconstr Surg. 2001;108:1576–81.CrossRef Pistre V, Pelissier P, Martin D, Lim A, Baudet J. Ten years of experience with the submental flap. Plast Reconstr Surg. 2001;108:1576–81.CrossRef
24.
Zurück zum Zitat Magden O, Edizer M, Tayfur V, Atabey A. Anatomic study of the vasculature of the submental artery flap. Plast Reconstr Surg. 2004;114:1719–23.CrossRef Magden O, Edizer M, Tayfur V, Atabey A. Anatomic study of the vasculature of the submental artery flap. Plast Reconstr Surg. 2004;114:1719–23.CrossRef
25.
Zurück zum Zitat Mayo-Smith WW, Hara AK, Mahesh M, Sahani DV, Pavlicek W. How I do it: managing radiation dose in CT. Radiology. 2014;273:657–72.CrossRef Mayo-Smith WW, Hara AK, Mahesh M, Sahani DV, Pavlicek W. How I do it: managing radiation dose in CT. Radiology. 2014;273:657–72.CrossRef
26.
Zurück zum Zitat Stacul F, van der Molen AJ, Reimer P, et al. Contrast induced nephropathy: updated ESUR contrast media safety committee guidelines. Eur Radiol. 2011;21:2527–41.CrossRef Stacul F, van der Molen AJ, Reimer P, et al. Contrast induced nephropathy: updated ESUR contrast media safety committee guidelines. Eur Radiol. 2011;21:2527–41.CrossRef
27.
Zurück zum Zitat Lind Ramskov K, Thomsen HS. Nephrogenic systemic fibrosis and contrast medium-induced nephropathy: a choice between the devil and the deep blue sea for patients with reduced renal function? Acta Radiol. 2009;50:965–7.CrossRef Lind Ramskov K, Thomsen HS. Nephrogenic systemic fibrosis and contrast medium-induced nephropathy: a choice between the devil and the deep blue sea for patients with reduced renal function? Acta Radiol. 2009;50:965–7.CrossRef
28.
Zurück zum Zitat Thomsen HS, Marckmann P, Logager VB. Enhanced computed tomography or magnetic resonance imaging: a choice between contrast medium-induced nephropathy and nephrogenic systemic fibrosis? Acta Radiol. 2007;48:593–6.CrossRef Thomsen HS, Marckmann P, Logager VB. Enhanced computed tomography or magnetic resonance imaging: a choice between contrast medium-induced nephropathy and nephrogenic systemic fibrosis? Acta Radiol. 2007;48:593–6.CrossRef
29.
Zurück zum Zitat Martin DR, Semelka RC, Chapman A, et al. Nephrogenic systemic fibrosis versus contrast-induced nephropathy: risks and benefits of contrast-enhanced MR and CT in renally impaired patients. J Magn Reson Imaging. 2009;30:1350–6.CrossRef Martin DR, Semelka RC, Chapman A, et al. Nephrogenic systemic fibrosis versus contrast-induced nephropathy: risks and benefits of contrast-enhanced MR and CT in renally impaired patients. J Magn Reson Imaging. 2009;30:1350–6.CrossRef
30.
Zurück zum Zitat Thomsen HS, Morcos SK, Almen T, et al. Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR contrast medium safety committee guidelines. Eur Radiol. 2013;23:307–18.CrossRef Thomsen HS, Morcos SK, Almen T, et al. Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR contrast medium safety committee guidelines. Eur Radiol. 2013;23:307–18.CrossRef
31.
Zurück zum Zitat Karunanithy N, Rose V, Lim AK, Mitchell A. CT angiography of inferior epigastric and gluteal perforating arteries before free flap breast reconstruction. Radiographics. 2011;31:1307–19.CrossRef Karunanithy N, Rose V, Lim AK, Mitchell A. CT angiography of inferior epigastric and gluteal perforating arteries before free flap breast reconstruction. Radiographics. 2011;31:1307–19.CrossRef
32.
Zurück zum Zitat Lam DL, Mitsumori LM, Neligan PC, Warren BH, Shuman WP, Dubinsky TJ. Pre-operative CT angiography and three-dimensional image post processing for deep inferior epigastric perforator flap breast reconstructive surgery. Br J Radiol. 2012;85:e1293–7.CrossRef Lam DL, Mitsumori LM, Neligan PC, Warren BH, Shuman WP, Dubinsky TJ. Pre-operative CT angiography and three-dimensional image post processing for deep inferior epigastric perforator flap breast reconstructive surgery. Br J Radiol. 2012;85:e1293–7.CrossRef
Metadaten
Titel
Non-contrast-enhanced magnetic resonance angiography of facial arteries for pre-operative evaluation of vascularized submental lymph node flaps
verfasst von
Ming-Chen Wu
Ming-Yi Hsu
Ren-Fu Shie
Ming-Huei Cheng
Fang-I Chu
Chien-Yuan Lin
Yui-Ping Fan
Sung-Yu Chu
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
BMC Medical Imaging / Ausgabe 1/2019
Elektronische ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-019-0368-7

Weitere Artikel der Ausgabe 1/2019

BMC Medical Imaging 1/2019 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.