Skip to main content
Erschienen in: Odontology 2/2022

27.08.2021 | Original Article

Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent

verfasst von: Pedro Ferrás Fernandes, Liliana Grenho, Maria Helena Fernandes, João Carlos Sampaio-Fernandes, Pedro Sousa Gomes

Erschienen in: Odontology | Ausgabe 2/2022

Einloggen, um Zugang zu erhalten

Abstract

The present study aims to characterize, for the first time, the microgap and bacterial microleakage of a platform-switched implant system with hybrid connection, screwed at distinct torque values (manufacturer recommended torque—25 N cm—and a reduced torque—5 N cm—mimicking the long-term functional use), in the absence or presence of a silicon-based sealing agent. Microgap was determined through scanning electron microscopy and bacterial microleakage was evaluated in vitro, upon Enterococcus faecalis colonization of the system. The sealing efficacy was evaluated in the absence or presence of a commercially available silicon-based sealer. The cytotoxicity of the sealer was further addressed in vitro, with a fibroblastic cell line, in accordance with reference standards. A low microgap of the implant system was verified, regardless of the applied torque load—maximal values ranged around 0.25 and 1.25 µm, for 25 and 5 N cm torques, respectively. No bacterial microleakage was reported at 25 N cm, while at 5 N cm, leakage was verified on 38% of the samples. The application of a silicon-based sealer—with an adequate cytocompatible profile—was effective on preventing the bacterial microleakage on the assayed experimental setting. The assayed platform-switched implant system with hybrid connection presented a low interfacial misfit and an effective sealing capability at manufacturer recommended torque. Despite the increased microleakage at low torque conditions, the application of a cytocompatible silicon-based sealing agent restored the sealing effectiveness of the system. The use of a silicon-based sealing agent can assist on the maintenance of the sealing effectiveness even at low torque conditions.
Literatur
1.
Zurück zum Zitat Payant L, Williams JE, Zwemer JD. Survey of dental implant practice. J Oral Implantol. 1994;20(1):50–8.PubMed Payant L, Williams JE, Zwemer JD. Survey of dental implant practice. J Oral Implantol. 1994;20(1):50–8.PubMed
2.
Zurück zum Zitat Misch CE. Endosteal implants for posterior single tooth replacement: alternatives, indications, contraindications, and limitations. J Oral Implantol. 1999;25(2):80–94.PubMedCrossRef Misch CE. Endosteal implants for posterior single tooth replacement: alternatives, indications, contraindications, and limitations. J Oral Implantol. 1999;25(2):80–94.PubMedCrossRef
3.
Zurück zum Zitat Vigolo P, Givani A. Platform-switched restorations on wide-diameter implants: a 5-year clinical prospective study. Int J Oral Maxillofac Implants. 2009;24(1):103–9.PubMed Vigolo P, Givani A. Platform-switched restorations on wide-diameter implants: a 5-year clinical prospective study. Int J Oral Maxillofac Implants. 2009;24(1):103–9.PubMed
4.
Zurück zum Zitat Suarez-Lopez Del Amo F, Lin GH, Monje A, Galindo-Moreno P, Wang HL. Influence of soft tissue thickness on peri-implant marginal bone loss: a systematic review and meta-analysis. J Periodontol. 2016;87(6):690–9.PubMedCrossRef Suarez-Lopez Del Amo F, Lin GH, Monje A, Galindo-Moreno P, Wang HL. Influence of soft tissue thickness on peri-implant marginal bone loss: a systematic review and meta-analysis. J Periodontol. 2016;87(6):690–9.PubMedCrossRef
5.
Zurück zum Zitat Galindo-Moreno P, Leon-Cano A, Ortega-Oller I, Monje A, O’Valle F, Catena A. Marginal bone loss as success criterion in implant dentistry: beyond 2 mm. Clin Oral Implants Res. 2015;26(4):e28–34.PubMedCrossRef Galindo-Moreno P, Leon-Cano A, Ortega-Oller I, Monje A, O’Valle F, Catena A. Marginal bone loss as success criterion in implant dentistry: beyond 2 mm. Clin Oral Implants Res. 2015;26(4):e28–34.PubMedCrossRef
6.
Zurück zum Zitat Andreasi Bassi M, Lopez MA, Confalone L, Gaudio RM, Lombardo L, Lauritano D. Clinical outcome of a two-piece implant system with an internal hexagonal connection: a prospective study. J Biol Regul Homeost Agents. 2016;30(2 Suppl 1):7–12.PubMed Andreasi Bassi M, Lopez MA, Confalone L, Gaudio RM, Lombardo L, Lauritano D. Clinical outcome of a two-piece implant system with an internal hexagonal connection: a prospective study. J Biol Regul Homeost Agents. 2016;30(2 Suppl 1):7–12.PubMed
7.
Zurück zum Zitat Scarano A, Assenza B, Piattelli M, Iezzi G, Leghissa GC, Quaranta A, et al. A 16-year study of the microgap between 272 human titanium implants and their abutments. J Oral Implantol. 2005;31(6):269–75.PubMedCrossRef Scarano A, Assenza B, Piattelli M, Iezzi G, Leghissa GC, Quaranta A, et al. A 16-year study of the microgap between 272 human titanium implants and their abutments. J Oral Implantol. 2005;31(6):269–75.PubMedCrossRef
8.
Zurück zum Zitat Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagn Res. 2017;11(6):ZE10–ZE5. Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagn Res. 2017;11(6):ZE10–ZE5.
9.
Zurück zum Zitat Quirynen M, van Steenberghe D. Bacterial colonization of the internal part of two-stage implants. An in vivo study. Clin Oral Implants Res. 1993;4(3):158–61.PubMedCrossRef Quirynen M, van Steenberghe D. Bacterial colonization of the internal part of two-stage implants. An in vivo study. Clin Oral Implants Res. 1993;4(3):158–61.PubMedCrossRef
10.
Zurück zum Zitat Nascimento C, Pita MS, Santos Ede S, Monesi N, Pedrazzi V, Albuquerque Junior RF, et al. Microbiome of titanium and zirconia dental implants abutments. Dent Mater. 2016;32(1):93–101.PubMedCrossRef Nascimento C, Pita MS, Santos Ede S, Monesi N, Pedrazzi V, Albuquerque Junior RF, et al. Microbiome of titanium and zirconia dental implants abutments. Dent Mater. 2016;32(1):93–101.PubMedCrossRef
11.
Zurück zum Zitat Liu Y, Wang J. Influences of microgap and micromotion of implant–abutment interface on marginal bone loss around implant neck. Arch Oral Biol. 2017;83:153–60.PubMedCrossRef Liu Y, Wang J. Influences of microgap and micromotion of implant–abutment interface on marginal bone loss around implant neck. Arch Oral Biol. 2017;83:153–60.PubMedCrossRef
12.
Zurück zum Zitat Broggini N, McManus LM, Hermann JS, Medina R, Schenk RK, Buser D, et al. Peri-implant inflammation defined by the implant–abutment interface. J Dent Res. 2006;85(5):473–8.PubMedCrossRef Broggini N, McManus LM, Hermann JS, Medina R, Schenk RK, Buser D, et al. Peri-implant inflammation defined by the implant–abutment interface. J Dent Res. 2006;85(5):473–8.PubMedCrossRef
13.
Zurück zum Zitat Park SD, Lee Y, Kim YL, Yu SH, Bae JM, Cho HW. Microleakage of different sealing materials in access holes of internal connection implant systems. J Prosthet Dent. 2012;108(3):173–80.PubMedCrossRef Park SD, Lee Y, Kim YL, Yu SH, Bae JM, Cho HW. Microleakage of different sealing materials in access holes of internal connection implant systems. J Prosthet Dent. 2012;108(3):173–80.PubMedCrossRef
14.
Zurück zum Zitat Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant–abutment interface. Int J Oral Maxillofac Implants. 1997;12(4):527–40.PubMed Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant–abutment interface. Int J Oral Maxillofac Implants. 1997;12(4):527–40.PubMed
15.
Zurück zum Zitat Canullo L, Penarrocha-Oltra D, Soldini C, Mazzocco F, Penarrocha M, Covani U. Microbiological assessment of the implant–abutment interface in different connections: cross-sectional study after 5 years of functional loading. Clin Oral Implants Res. 2015;26(4):426–34.PubMedCrossRef Canullo L, Penarrocha-Oltra D, Soldini C, Mazzocco F, Penarrocha M, Covani U. Microbiological assessment of the implant–abutment interface in different connections: cross-sectional study after 5 years of functional loading. Clin Oral Implants Res. 2015;26(4):426–34.PubMedCrossRef
16.
Zurück zum Zitat Karl M, Taylor TD. Parameters determining micromotion at the implant–abutment interface. Int J Oral Maxillofac Implants. 2014;29(6):1338–47.PubMedCrossRef Karl M, Taylor TD. Parameters determining micromotion at the implant–abutment interface. Int J Oral Maxillofac Implants. 2014;29(6):1338–47.PubMedCrossRef
17.
Zurück zum Zitat Lazzara RJ, Porter SS. Platform-switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restor Dent. 2006;26(1):9–17. Lazzara RJ, Porter SS. Platform-switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restor Dent. 2006;26(1):9–17.
18.
Zurück zum Zitat Atieh MA, Ibrahim HM, Atieh AH. Platform-switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 2010;81(10):1350–66.PubMedCrossRef Atieh MA, Ibrahim HM, Atieh AH. Platform-switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 2010;81(10):1350–66.PubMedCrossRef
19.
Zurück zum Zitat Strietzel FP, Neumann K, Hertel M. Impact of platform-switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis. Clin Oral Implants Res. 2015;26(3):342–58.PubMedCrossRef Strietzel FP, Neumann K, Hertel M. Impact of platform-switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis. Clin Oral Implants Res. 2015;26(3):342–58.PubMedCrossRef
20.
Zurück zum Zitat Santiago JF Jr, Batista VE, Verri FR, Honorio HM, de Mello CC, Almeida DA, et al. Platform-switching implants and bone preservation: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2016;45(3):332–45.PubMedCrossRef Santiago JF Jr, Batista VE, Verri FR, Honorio HM, de Mello CC, Almeida DA, et al. Platform-switching implants and bone preservation: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2016;45(3):332–45.PubMedCrossRef
21.
Zurück zum Zitat Lauritano D, Moreo G, Lucchese A, Viganoni C, Limongelli L, Carinci F. The impact of implant–abutment connection on clinical outcomes and microbial colonization: a narrative review. Materials (Basel). 2020;13(5):1131. Lauritano D, Moreo G, Lucchese A, Viganoni C, Limongelli L, Carinci F. The impact of implant–abutment connection on clinical outcomes and microbial colonization: a narrative review. Materials (Basel). 2020;13(5):1131.
22.
Zurück zum Zitat Dental S, Candotto V, Gabrione F, Oberti L, Lento D, Severino M. The role of implant–abutment connection in preventing bacterial leakage: a review. J Biol Regul Homeost Agents. 2019;33(3 Suppl. 1):129–34. Dental S, Candotto V, Gabrione F, Oberti L, Lento D, Severino M. The role of implant–abutment connection in preventing bacterial leakage: a review. J Biol Regul Homeost Agents. 2019;33(3 Suppl. 1):129–34.
23.
Zurück zum Zitat Besimo CE, Guindy JS, Lewetag D, Meyer J. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants. 1999;14(5):654–60.PubMed Besimo CE, Guindy JS, Lewetag D, Meyer J. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants. 1999;14(5):654–60.PubMed
24.
Zurück zum Zitat Nayak AG, Fernandes A, Kulkarni R, Ajantha GS, Lekha K, Nadiger R. Efficacy of antibacterial sealing gel and O-ring to prevent microleakage at the implant abutment interface: an in vitro study. J Oral Implantol. 2014;40(1):11–4.PubMedCrossRef Nayak AG, Fernandes A, Kulkarni R, Ajantha GS, Lekha K, Nadiger R. Efficacy of antibacterial sealing gel and O-ring to prevent microleakage at the implant abutment interface: an in vitro study. J Oral Implantol. 2014;40(1):11–4.PubMedCrossRef
25.
Zurück zum Zitat Coelho PG, Sudack P, Suzuki M, Kurtz KS, Romanos GE, Silva NR. In vitro evaluation of the implant abutment connection sealing capability of different implant systems. J Oral Rehabil. 2008;35(12):917–24.PubMedCrossRef Coelho PG, Sudack P, Suzuki M, Kurtz KS, Romanos GE, Silva NR. In vitro evaluation of the implant abutment connection sealing capability of different implant systems. J Oral Rehabil. 2008;35(12):917–24.PubMedCrossRef
26.
Zurück zum Zitat Lorenzoni FC, Coelho PG, Bonfante G, Carvalho RM, Silva NR, Suzuki M, et al. Sealing capability and SEM observation of the implant–abutment interface. Int J Dent. 2011;2011:864183.PubMedPubMedCentralCrossRef Lorenzoni FC, Coelho PG, Bonfante G, Carvalho RM, Silva NR, Suzuki M, et al. Sealing capability and SEM observation of the implant–abutment interface. Int J Dent. 2011;2011:864183.PubMedPubMedCentralCrossRef
27.
Zurück zum Zitat Seloto CB, Strazzi-Sahyon HB, Dos Santos PH, Assuncao WG. Effectiveness of sealing gel on vertical misfit at the implant–abutment interface and preload maintenance of screw-retained implant-supported prostheses. Int J Oral Maxillofac Implants. 2020;35(3):479–84.PubMedCrossRef Seloto CB, Strazzi-Sahyon HB, Dos Santos PH, Assuncao WG. Effectiveness of sealing gel on vertical misfit at the implant–abutment interface and preload maintenance of screw-retained implant-supported prostheses. Int J Oral Maxillofac Implants. 2020;35(3):479–84.PubMedCrossRef
28.
Zurück zum Zitat Annibali S, Bignozzi I, Cristalli MP, Graziani F, La Monaca G, Polimeni A. Peri-implant marginal bone level: a systematic review and meta-analysis of studies comparing platform-switching versus conventionally restored implants. J Clin Periodontol. 2012;39(11):1097–113.PubMedCrossRef Annibali S, Bignozzi I, Cristalli MP, Graziani F, La Monaca G, Polimeni A. Peri-implant marginal bone level: a systematic review and meta-analysis of studies comparing platform-switching versus conventionally restored implants. J Clin Periodontol. 2012;39(11):1097–113.PubMedCrossRef
29.
Zurück zum Zitat Schmitt CM, Nogueira-Filho G, Tenenbaum HC, Lai JY, Brito C, Doring H, et al. Performance of conical abutment (Morse Taper) connection implants: a systematic review. J Biomed Mater Res A. 2014;102(2):552–74.PubMedCrossRef Schmitt CM, Nogueira-Filho G, Tenenbaum HC, Lai JY, Brito C, Doring H, et al. Performance of conical abutment (Morse Taper) connection implants: a systematic review. J Biomed Mater Res A. 2014;102(2):552–74.PubMedCrossRef
30.
Zurück zum Zitat Tsuruta K, Ayukawa Y, Matsuzaki T, Kihara M, Koyano K. The influence of implant–abutment connection on the screw loosening and microleakage. Int J Implant Dent. 2018;4(1):11.PubMedPubMedCentralCrossRef Tsuruta K, Ayukawa Y, Matsuzaki T, Kihara M, Koyano K. The influence of implant–abutment connection on the screw loosening and microleakage. Int J Implant Dent. 2018;4(1):11.PubMedPubMedCentralCrossRef
31.
Zurück zum Zitat Gherlone EF, Cappare P, Pasciuta R, Grusovin MG, Mancini N, Burioni R. Evaluation of resistance against bacterial microleakage of a new conical implant–abutment connection versus conventional connections: an in vitro study. New Microbiol. 2016;39(1):49–56.PubMed Gherlone EF, Cappare P, Pasciuta R, Grusovin MG, Mancini N, Burioni R. Evaluation of resistance against bacterial microleakage of a new conical implant–abutment connection versus conventional connections: an in vitro study. New Microbiol. 2016;39(1):49–56.PubMed
32.
Zurück zum Zitat Kofron MD, Carstens M, Fu C, Wen HB. In vitro assessment of connection strength and stability of internal implant–abutment connections. Clin Biomech (Bristol, Avon). 2019;65:92–9.CrossRef Kofron MD, Carstens M, Fu C, Wen HB. In vitro assessment of connection strength and stability of internal implant–abutment connections. Clin Biomech (Bristol, Avon). 2019;65:92–9.CrossRef
33.
Zurück zum Zitat Toyoshima T, Tanaka H, Ayukawa Y, Howashi M, Masuzaki T, Kiyosue T, et al. Primary stability of a hybrid implant compared with tapered and cylindrical implants in an ex vivo model. Clin Implant Dent Relat Res. 2015;17(5):950–6.PubMedCrossRef Toyoshima T, Tanaka H, Ayukawa Y, Howashi M, Masuzaki T, Kiyosue T, et al. Primary stability of a hybrid implant compared with tapered and cylindrical implants in an ex vivo model. Clin Implant Dent Relat Res. 2015;17(5):950–6.PubMedCrossRef
34.
Zurück zum Zitat Sammour SR, Maamoun El-Sheikh M, Aly E-G. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35(11):e265–71.PubMedCrossRef Sammour SR, Maamoun El-Sheikh M, Aly E-G. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35(11):e265–71.PubMedCrossRef
35.
Zurück zum Zitat Velez J, Pelaez J, Lopez-Suarez C, Agustin-Panadero R, Tobar C, Suarez MJ. Influence of implant connection, abutment design and screw insertion torque on implant–abutment misfit. J Clin Med. 2020;9(8):2365. Velez J, Pelaez J, Lopez-Suarez C, Agustin-Panadero R, Tobar C, Suarez MJ. Influence of implant connection, abutment design and screw insertion torque on implant–abutment misfit. J Clin Med. 2020;9(8):2365.
36.
Zurück zum Zitat Gehrke SA, Delgado-Ruiz RA, Prados Frutos JC, Prados-Privado M, Dedavid BA, Granero Marin JM, et al. Misfit of three different implant–abutment connections before and after cyclic load application: an in vitro study. Int J Oral Maxillofac Implants. 2017;32(4):822–9.PubMedCrossRef Gehrke SA, Delgado-Ruiz RA, Prados Frutos JC, Prados-Privado M, Dedavid BA, Granero Marin JM, et al. Misfit of three different implant–abutment connections before and after cyclic load application: an in vitro study. Int J Oral Maxillofac Implants. 2017;32(4):822–9.PubMedCrossRef
37.
Zurück zum Zitat Baggi L, Di Girolamo M, Mirisola C, Calcaterra R. Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant–abutment interfaces and closing torque values. Implant Dent. 2013;22(4):344–50.PubMedCrossRef Baggi L, Di Girolamo M, Mirisola C, Calcaterra R. Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant–abutment interfaces and closing torque values. Implant Dent. 2013;22(4):344–50.PubMedCrossRef
38.
Zurück zum Zitat Smith NA, Turkyilmaz I. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values. J Prosthet Dent. 2014;112(3):561–7.PubMedCrossRef Smith NA, Turkyilmaz I. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values. J Prosthet Dent. 2014;112(3):561–7.PubMedCrossRef
39.
Zurück zum Zitat Zipprich H, Rathe F, Pinz S, Schlotmann L, Lauer HC, Ratka C. Effects of screw configuration on the preload force of implant–abutment screws. Int J Oral Maxillofac Implants. 2018;33(2):e25–32.PubMedCrossRef Zipprich H, Rathe F, Pinz S, Schlotmann L, Lauer HC, Ratka C. Effects of screw configuration on the preload force of implant–abutment screws. Int J Oral Maxillofac Implants. 2018;33(2):e25–32.PubMedCrossRef
40.
41.
Zurück zum Zitat Najafi K, Ganbarov K, Gholizadeh P, Tanomand A, Rezaee M, Mahmood S, et al. Oral cavity infection by Enterococcus faecalis: virulence factors and pathogenesis. Rev Med Microbiol. 2020;31:51–60.CrossRef Najafi K, Ganbarov K, Gholizadeh P, Tanomand A, Rezaee M, Mahmood S, et al. Oral cavity infection by Enterococcus faecalis: virulence factors and pathogenesis. Rev Med Microbiol. 2020;31:51–60.CrossRef
42.
Zurück zum Zitat de Sousa CA, Taborda MBB, Momesso GAC, Rocha EP, Dos Santos PH, Santiago-Junior JF, et al. Materials sealing preventing biofilm formation in implant/abutment joints: which is the most effective? A systematic review and meta-analysis. J Oral Implantol. 2020;46(2):163–71.PubMedCrossRef de Sousa CA, Taborda MBB, Momesso GAC, Rocha EP, Dos Santos PH, Santiago-Junior JF, et al. Materials sealing preventing biofilm formation in implant/abutment joints: which is the most effective? A systematic review and meta-analysis. J Oral Implantol. 2020;46(2):163–71.PubMedCrossRef
43.
Zurück zum Zitat Najafloo R, Behyari M, Imani R, Nour S. A mini-review of Thymol incorporated materials: applications in antibacterial wound dressing. J Drug Deliv Sci Technol. 2020;60:101904. Najafloo R, Behyari M, Imani R, Nour S. A mini-review of Thymol incorporated materials: applications in antibacterial wound dressing. J Drug Deliv Sci Technol. 2020;60:101904.
44.
Zurück zum Zitat Colas A, Curtis J. Silicones. In: Modjarrad K, Ebnesajjad S, editors. Handbook of polymer applications in medicine and medical devices. New York: William Andrew Publishing; 2013. p. 131–43.CrossRef Colas A, Curtis J. Silicones. In: Modjarrad K, Ebnesajjad S, editors. Handbook of polymer applications in medicine and medical devices. New York: William Andrew Publishing; 2013. p. 131–43.CrossRef
45.
Zurück zum Zitat Costa MF, Durco AO, Rabelo TK, Barreto RSS, Guimaraes AG. Effects of Carvacrol, Thymol and essential oils containing such monoterpenes on wound healing: a systematic review. J Pharm Pharmacol. 2019;71(2):141–55.PubMedCrossRef Costa MF, Durco AO, Rabelo TK, Barreto RSS, Guimaraes AG. Effects of Carvacrol, Thymol and essential oils containing such monoterpenes on wound healing: a systematic review. J Pharm Pharmacol. 2019;71(2):141–55.PubMedCrossRef
Metadaten
Titel
Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent
verfasst von
Pedro Ferrás Fernandes
Liliana Grenho
Maria Helena Fernandes
João Carlos Sampaio-Fernandes
Pedro Sousa Gomes
Publikationsdatum
27.08.2021
Verlag
Springer Singapore
Erschienen in
Odontology / Ausgabe 2/2022
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-021-00652-x

Weitere Artikel der Ausgabe 2/2022

Odontology 2/2022 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.